Stainless steel sensor
Laboratory, environmental industry
Features
-
nominal pressure: 0 ... 400 mbar up to 0 ... 40 bar
-
accuracy: 0.1 % FSO
-
thermal error in compensated range -20 … 80 °C: 0.2 % FSO TC 0.02 % FSO / 10 K
-
turn-down 1:10
-
communication interface for adjusting of offset, span and damping
Optional Features
-
IS-version
Ex ia = intrinsically safe for gases and dusts -
adjustment of nominal pressure gauges (factory-provided)
Ceramic sensor (flush)
Environmental industry, renewable energy
Features
-
nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar
-
accuracy: 0.35 % (opt. 0.25 %) FSO
-
pressure port G 1 1/2" for pasty and polluted media
Optional Features
-
IS-version
Ex ia = intrinsically for gases and dusts -
pressure port PVDF for aggressive media
-
diaphragm pure ceramic (99.9 % Al2O3)
-
customer specific versions
Stainless steel sensor
Plant and mechanical engineering
Features
-
nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
-
accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
-
small thermal effect
-
excellent long term stability
-
pressure port G 3/4" flush
Optional Features
-
IS-version
Ex ia = intrinsically safe for gases and dusts -
SIL 2 application according to IEC 61508 / IEC 61511
-
different electrical connections
-
customer specific versions
Ceramic sensor (flush)
Plant and mechanical engineering
Features
-
nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar
-
accuracy: 0.5 % FSO
-
pressure port G 3/4" flush
Optional Features
-
IS-version (only for 4... 20 mA / 2-wire):
Ex ia = intrinsically safe for gases and dusts -
SIL 2 application according to IEC 61508 / IEC 61511
-
pressure port PVDF for aggressive media
-
different electrical and mechanical connections
-