top of page
Logo BDSensors.png
Digital pressure gauge
BDSensors DM01.jpg

Stainless steel sensor 
Test and calibration equipment

Features

  • nominal pressure: 0 ... 100 mbar up to 0 ... 400 bar

  • accuracy: 0.05 % FSO BFSL (class 0.05)

  • graphics-capable display 

  • background illumination 

  • communication interface USB 2.0 

  • stainless steel housing d = 100 mm 

  • zero point calibration 

  • data logger

Optional Features

  • accredited calibration certificate according to DKD / DAkkS

  • IS-version zone 1

  • service case with accessories

  • software incl. USB converter

BDSensors BAROLI05.jpg

BAROLI 05

Ceramic sensor 
Laboratory, environmental industry

Features

  • nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar

  • accuracy: 0.25 % FSO BFSL (class 0.2)

  • rotatable housing 

  • 2-line LC display, 4,5-digit 7-segment display, 6-digit 14-segment additional display 

  • different mechanical connections: inch, NPT threads 

  • ceramic diaphragm

Optional Features

  • min / max function with reset function

  • offset and end point calibration

  • setting the pressure unit

  • switch-off automatic configuration

BDSensors DM10.jpg

Ceramic sensor 
Plant and mechanical engineering

Features

  • nominal pressure: 0 ... 1,6 bar up to 0 ... 250 bar

  • accuracy: 0.5 % FSO BFSL (class 0.5)

  • ceramic diaphragm 

  • adjustable housing 

  • LC display, 4,5-digit 7-segment display 

  • standard battery CR 2450 operating period > 1.500h

Optional Features

  • min / max function with reset function

  • auto-zero

  • setting the pressure unit

  • automatic switch-off cofiguration

BDSensors DL01.jpg

Stainless steel sensor 
Leak testing, pipeline monitoring

Features

  • nominal pressure: 0 …100 mbar up to 0 ... 400 bar

  • accuracy: 0.05 % FSO BFSL (Klasse 0.05)

  • data logger 

  • graphics-capable display 

  • stainless steel housing d = 100 mm 

  • communication interface USB 2.0

​Optional Features

  • data logger interval 1s ... 99 days or fixed time

  • default values for time / test duration

  • zero point calibration

  • software incl. USB converter

  • backlight and much more

BDSensors BAROLI02P.jpg

BAROLI 02P

Stainless steel sensor (flush) 
Hygienic applications

Features

  • nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar

  • accuracy: 0.125 % FSO BFSL (class 0.1)

  • 2-line LC display, 4,5-digit 7-segment display, 6-digit 14-segment additional display 

  • hygienic process connections, EHEDG-conformity 

  • rotatable housing 

  • flush welded stainless steel diaphragm

Optional Features

  • min / max function with reset function

  • offset and end point calibration

  • setting the pressure unit

  • configuration of switch-off automatic

BDSensors DM17.jpg

Stainless steel sensor 
Plant and machine engineering

Features

  • nominal pressure: 0 ... 6 bar up to 0 ... 600 bar

  • accuracy: 0.5 % FSO BFSL (class 0.5)

  • adjustable housing 

  • LC display, 4,5-digit 7-segment display 

  • standard battery CR 2450 operating period > 1.500h

Optional Features

  • min / max function with reset function

  • auto-zero

  • setting the pressure unit

  • automatic switch-off cofiguration

BDSensors BAROLI02.jpg

BAROLI 02

Stainless steel sensor 
Laboratory, environmental industry

Features

  • nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar

  • accuracy: 0.125 % FSO BFSL (class 0.1)

  • stainless steel diaphragm 

  • 2-line LC display, 4,5-digit 7-segment display, 6-digit 14-segment additional display 

  • different mechanical connections: inch, NPT threads 

  • rotatable housing

Optional Features

  • min- / max-function with reset function

  • offset and end point calibration

  • setting the pressure unit

  • switch-off automatic

BDSensors BAROLI05P.jpg

BAROLI 05P

Stainless steel sensor (flush) 
Hygienic applications

Features

  • nominal pressure: 0 ... 60 bar up to 0 ... 400 bar

  • accuracy: 0.25 % FSO BFSL (class 0.2)

  • flush welded stainless steel diaphragm 

  • rotatable housing 

  • 2-line LC display, 4,5-digit 7-segment display, 6-digit 14-segment additional display 

  • suited for viscous and pasty media

Optional Features

  • min / max function with reset function

  • offset and end point calibration

  • setting the pressure unit

  • switch-off automatic configuration

bottom of page